Reverse Osmosis System Maintenance Guide (+ Servicing Schedule)

14 Oct.,2022

 

Seawater Desalination RO Membranes

Written by: Gene Fitzgerald // Last Updated: Oct 6, 2022

Please note: This page may contain affiliate links. If you buy a product or service through such a link we earn a commission at no additional cost to you. Learn more about our product review process or check our FTC affiliate disclosure.

If properly maintained, a reverse osmosis system provides you with clean, healthy and great tasting drinking water.

Furthermore, a unit that’s kept in great shape can last for many years, even more than a decade. Fail to do so, however, and you may end up with contaminated water.

The good news is that the required maintenance is low. Also, regular filter and membrane replacements and system cleaning/sterilizing can be done by the average homeowner without the need to be an expert plumber. Want to learn more? Read on!

Contents

Key Takeaways

How to maintain a reverse osmosis system:

  • Changing the pre and post-filters on a regular basis is key.
  • Pre-filters should be replaced about every 6 to 12 months. Most post-filters last 1-2 years.
  • RO membranes usually last for up to 2 to 5 years (if you replace pre-filters according to schedule).
  • You should clean/sanitize your system with each filter replacement; ideally 1-2 times a year.
  • Check the storage tank pressure using a low-pressure gauge at least once a year. Measure the pressure when your tank is empty. 6-8 psi is ideal. Repressurize using a bicycle pump if needed.

Reverse Osmosis Maintenance Schedule

This reverse osmosis maintenance schedule will help you stay on time with the different tasks:

Biannual TasksAnnual TasksEvery 3 to 5 YearsReplacing pre-filtersReplacing pre-filtersReplacing post-filter(s)Replacing RO membraneSystem cleaning/sanitizingChecking storage tank pressure

Reverse Osmosis System Maintenance: Filter Changes

The most important aspect of maintaining your reverse osmosis system is to change the pre and post-filters on a regular basis.

How often?

This depends first and foremost on the condition of the feed water and your water consumption. For example: Hardness or high levels of sediment as often found in well water can lower the lifespan of the pre-filter elements significantly. And, of course, the more water you use for drinking and cooking, the sooner your filters will wear out.

As a rule of thumb, pre-filters should be replaced at least every 6 to 12 months. A carbon post-filter can last as long as 2 years. In addition, cheap filters might require more frequent replacements as they tend to wear out quicker. For more information we recommend that you refer to the user manual.

On a side note: It is essential that you get the correct filters for your unit. Almost all manufacturers sell replacement parts including filters, so visit their website first. If you are going to buy from another source double-check that the quality is up to standards.

One thing is for certain, failing to change filters in a timely manner will

  • Decrease the overall purity of the output water.
  • Favor accumulation and growth of waterborne pathogens (fouling) in the filtration system. This mold, mildew, bacteria, etc. may pose a health threat.
  • Lead to a drop in output water volume, so flow and pressure.
  • Cause higher wastewater production which ultimately increases your water bill.

Bottom line: Make sure that you stay on schedule and change filters (and the membrane – more info below) in due time.

By the way, all 4 aspects listed above can be taken as clear indicators that filter replacements are overdue. What’s more, you might notice an unpleasant taste and/or odor in your water.

Sediment Pre-Filter

Stage 1 of the vast majority of reverse osmosis water filter systems makes use of a sediment pre-filter. The goal is to protect the delicate RO membrane at the heart of the system from clogging – clogging from dirt, rust, silt and other kinds of debris which get trapped in the filter.

You should replace the sediment pre-filter every 6 to 12 months.

Changing the filters of your old RO system doesn’t make much sense anymore? You might be better off with an entirely new unit – reviews here.

Carbon Pre-Filters

Usually at stage 2 & 3, carbon pre-filters come into play. Activated/catalytic carbon or charcoal is great for removing chemicals from water, first and foremost chlorine and other disinfectants, which would otherwise affect the performance of the reverse osmosis membrane. Thin film composite (TFC) membranes are particularly susceptible to free chlorine.

Block or granular – carbon pre-filters require changing every 6 to 12 months.

Did we mention that a carbon filter also greatly improves water aesthetics?

Carbon Post-Filter

And lastly, we have a carbon post-filter (filtration stage 4 or 5). It has the purpose to give your water a refining touch right before it comes out of the faucet. The carbon removes any residual tastes and odors that may have leached into the water while being stored in the pressure tank.

Carbon post-filters should be changed about every 12 months. Some may even be good for up to 2 years.

How to Replace Filters

Before you attempt to replace your system’s filters make sure to take a look in the product manual. It likely includes specific step-by-step instructions not only for filter/membrane replacements, but also for other maintenance works.

This will give you a basic idea of the process (keep in mind that every model is a bit different):

  1. Turn off the water supply and storage tank valve.
  2. Depressurize the system.
  3. Remove filters/membrane from their housings.
  4. Insert new elements and screw the housings back on.
  5. Turn on the water supply and open the tank valve.
  6. Open the RO faucet and let the system flush for a couple of minutes.
  7. Check for leaks.
  8. Close the faucet to let the tank refill.
  9. Discard 1 or 2 full tanks of water before use (might not be necessary depending on your system).

RO Membrane Replacements

What about the RO membrane?

A semipermeable reverse osmosis membrane that is in good condition removes up to 99% of all remaining contaminants from your water. This includes lead, arsenic, fluoride, chromium, 98-99% of waterborne pathogens and much more. TDS drop to almost 0.

RO membranes last longer than the various filters, not seldom up to 3 or 5 years, provided that you replace pre-filters according to schedule. In some applications, a new RO membrane is required every 1 or 2 years.

FYI: The safest way to determine if your membrane needs changing is by using a TDS meter. If the rejection of output water TDS drops below 80% it is time for a replacement.

Again, to find out how you can replace your system’s RO membrane you should consult the manual.

System Cleaning & Sanitizing

Cleaning and sanitizing a reverse osmosis system is not necessary in all cases. However, the whole process is neither overly complicated nor time consuming, which is why we recommend you follow through with it to be on the safe side.

How often to clean/sanitize? With each filter replacement – ideally once a year, maybe twice if need be.

As always, for specific instructions refer to the owner’s manual. Alternatively, follow this link to learn how to clean and sanitize a reverse osmosis system. In a nutshell:

  1. Turn off the water supply.
  2. Depressurize the system.
  3. Remove all filters + membrane from their housings. Scrub the inside of the housings with warm dishwater. Rinse afterwards.
  4. Add unscented household bleach or another suited sanitizer into the housing of filter stage one.
  5. Screw all housings back on.
  6. Turn on the water supply.
  7. Open the RO faucet until water comes out. Then close it.
  8. Check for leaks.
  9. Let the storage tank fill and allow the bleach to stay in the system for at least 30 minutes and up to a couple of hours.
  10. Flush out all water.
  11. Let the tank refill a second time and flush out.
  12. Turn off the water supply.
  13. Depressurize the system.
  14. Install RO membrane and other filter elements.
  15. Turn the water supply back on.
  16. Open the RO faucet and let the system flush for a couple of minutes.
  17. Check for leaks.
  18. Close the faucet to let the tank fill.
  19. Discard 1 or 2 full tanks of water before use (might not be necessary depending on your system). Done!

Meanwhile, you can soak the membrane in different chemical solutions, depending on its type and as recommended by the manufacturer. This helps to eradicate organic matter and remove stuff like mold and mildew – think fouling. It will also prevent scaling. Both are important for optimum operating pressure, water output and water quality.

Checking Storage Tank Pressure

Adequate storage tank pressure is important for your RO system to function properly. Thus, you should check it about once a year. Any low pressure gauge will work fine for this.

FYI: A tank may lose about 1 psi per year.

What’s important is that you measure the pressure when your tank is empty. It should read somewhere around 6 – 8 psi. In case your tank is underpressurized you can use a simple bicycle pump to fix it.

Want more info on how to drain and repressurize an RO tank?

Reverse Osmosis Service

While most people choose to maintain their reverse osmosis system themselves, you have the option to hire a local water treatment specialist to do the work for you.

After-sales services are provided by a range of companies, so reach out to 2 or 3 and ask for prices for better comparison.

If you have any questions or thoughts about RO maintenance please don’t hesitate to leave a comment below!

About the Author Gene Fitzgerald

Gene Fitzgerald has been with BOS since the very beginning. She is head of content creation and has fully immersed herself into the home water treatment industry only to become an expert herself. Outside of BOS, Gene loves reading books on philosophy & social issues, making music, and hiking.
Learn more about Gene and the rest of the BOS Team.